
The HERO Inhaler 1800 delivers 1,200 ml/min of pure H₂ (1,800 ml/min total gas flow) — the highest output in our Professional Series below the HERO Inhaler Pro 3000, suited to users who prefer shorter, higher-concentration inhalation sessions. FCC Part 15 Subpart B compliance. PEM electrolysis with complete H₂/O₂ gas separation.
Inhale and drink from one machine. The included diffusion rod connects to the hydrogen outlet and makes hydrogen-rich water in a glass.
Professional Series
Heavy-duty build for clinics, studios and heavy daily use, with metal casing and castor wheels.
- Total gas: 1800 ml/min (H₂+O₂, 2:1)
- Adjustable output flow, so you can set the flow for each session or user.
- 1200 ml/min pure H₂ at 99.991% purity
- 16 kg chassis with recessed side carry handles
- 3.0 L purified water reservoir
- Universal 220 V input
- Session timer with auto-shutdown
- Built for long studio sessions
HERO Inhaler 1800 — White finish
- Model
- HERO Inhaler 1800
- Total gas output (H₂ + O₂)
- 1800 ml/min (natural 2:1 ratio, adjustable)
- Flow control
- Adjustable output. Set the flow to suit each session or user.
- Pure hydrogen stream
- 1200 ml/min at 99.991% purity
- Pure oxygen stream
- 600 ml/min at >99% purity (separated at the membrane)
- Combined H₂ + O₂ flow
- Up to 1800 ml/min via included Y connector (2:1)
- Membrane
- SPE / PEM hydrogen-separation stack
- Water reservoir
- 3.0 L purified water tank
- Water requirements
- Purified water / Distilled water, TDS < 5
- Water temperature
- 5–38 °C operating range
- Voltage
- 220 V ~ 50 Hz
- Noise level
- ≤ 48 dB at 1 m (quiet conversation)
- Power
- 530 W
- Weight
- 14 kg
- Dimensions
- 240 × 310 × 380 mm
- User capacity
- 2* users — with the dual cannula accessory
- Format
- Home unit
- Rated PEM stack service life
- 10,000 hours (≈10 years at 45 min/day)
- Warranty
- 2-Year Warranty
How inhaled and drunk hydrogen reach different parts of the body →
Side-by-side flow rates, H₂ output, purity, weight and price for every machine in the range.
Compare all 13 machines- 2-Year Warranty
- Delivered to your door by UPS with full tracking, duties paid. No customs fees on arrival. Up to 14 business days from order.
- 90-day returns (change-of-mind return shipping paid by the buyer)
- Message us on WhatsApp
- US customer service: (743) 962-7305
Founded by Dr Peter Griffiths, with four decades in hydrogen technology.
Ships to all 50 states, duties paid.
- Delivered to your door by UPS with full tracking, duties paid. No customs fees on arrival. Up to 14 business days from order.
- Engineered for 10,000 hours of continuous operation — roughly 10+ years at 45 minutes a day; that figure is the PEM stack's rated service life.
- 2-Year Warranty. Covers defects in materials and workmanship from the delivery date: free replacement parts with step-by-step video fitting guides; we pay the shipping in year 1, you cover it in year 2.
- 90-day returns. Change-of-mind return shipping is paid by the buyer; we cover it if a machine arrives damaged or faulty.
- Support by email and WhatsApp; replacement parts shipped directly to you.
What happens after you order
- 1You receive an order confirmation within minutes.
- 2Your order is processed by our fulfilment partner and handed to the carrier.
- 3Delivered to your door by UPS with full tracking, duties paid. No customs fees on arrival. Up to 14 business days from order.
- 4Unbox, plug in, and use. 90-day returns if it isn't for you.
- Customer Reviews
- 2-Year Warranty
- US Customer Support
- Secure Checkout — SSL Encrypted
Buy with confidence
Every machine comes with a 2-year warranty and 90-day returns, handled directly by us. Support by email and WhatsApp; replacement parts shipped directly to you.
Covers defects in materials and workmanship from the delivery date: free replacement parts with step-by-step video fitting guides; we pay the shipping in year 1, you cover it in year 2.
Change-of-mind return shipping is paid by the buyer; we cover it if a machine arrives damaged or faulty.
Our return rate is effectively zero. We ship only after pre-sale fit checks so the right machine reaches the right user the first time.
Support by email and WhatsApp; replacement parts shipped directly to you. Same-day reply during business hours at hello@hydrogenmachinesusa.com.
- Customer Reviews
- 2-Year Warranty
- US Customer Support
- Secure Checkout — SSL Encrypted
Quick answers
- What is the safest hydrogen inhaler technology?
- PEM (Proton Exchange Membrane) electrolysis separates hydrogen and oxygen at the membrane. Consult the chosen model's specifications and supporting documents for purity and safety evidence. Engineering descriptions refer to hardware, not medical or therapeutic status.
- How should I compare larger hydrogen inhalers?
- Compare published gas format, output, configuration and exact-model documentation. Equipment specifications do not establish medical or therapeutic suitability.
- What is the difference between HERO Inhaler and HERO Inhaler Pro?
- The HERO Inhaler range has several stated flow-rate tiers. HERO Inhaler Pro 3000 is listed with 3,000 ml/min combined output and dual-user support. Consult each model's specifications and documents.
- How should I compare mixed-gas hydrogen inhalers?
- Mixed-gas devices output hydrogen and oxygen together. AquaCure AC50/AC60 entries reflect manufacturer-stated specifications and professional documentation. AC50 output: up to 50 L/h (about 833 mL/min) of mixed hydrogen–oxygen gas, as published by Eagle-Research. Check exact-model documents rather than inferring safety or gas composition from the technology name.
- Is HX3000 a PEM hydrogen inhaler?
- The membrane type is not established here. Ask the seller for exact-model documentation. HERO Inhaler Pro 3000 is listed with PEM electrolysis; compare its published specifications.
- How should I compare flow rates?
- Check whether each reported figure describes hydrogen alone or combined hydrogen and oxygen. Compare measurement methods and the exact model's supported configuration.
- How should I compare safety documentation?
- Ask each seller for documents covering the exact model and listed safeguards. Hardware testing is not evidence of medical approval or therapeutic suitability.
- How should I choose a hydrogen inhaler?
- Compare published model specifications, gas format, configuration, warranty and support terms.
- How is hydrogen purity verified?
- Check the laboratory report's named model, measured outlet and test conditions. Report LH2025050017 covers HERO Inhaler 900, 1200, 1500, 1800 and Pro 3000; do not extend its results to other models or untested flow rates.
- How does PEM electrolysis differ from mixed-gas generation?
- PEM electrolysis uses a membrane-based cell design. Mixed-gas equipment outputs hydrogen and oxygen together. Neither technology name establishes a measured purity figure; check the exact model's documents.
- Which HERO models have laboratory documentation?
- Report LH2025050017 covers HERO Inhaler 900, 1200, 1500, 1800 and Pro 3000. Check the named model and measured outlet before relying on a result.
Certification and engineering claims describe hardware and manufacturing quality, not medical or therapeutic status.
Frequently asked questions
The HERO Inhaler / HERO Inhaler Pro PEM stack separates hydrogen and oxygen at the membrane. Breathe hydrogen alone from the H₂ outlet, join both outlets with the included Y connector for the combined 2:1 hydrogen-oxygen flow, or split the machine between two users with the dual cannula. See the instructional video in the How-To-Use section on the product page for step-by-step setup of each mode.
No. Every machine we sell is a general wellness device, not a medical device. No medical registration or approval is claimed. No disease, diagnostic or treatment claims are made.
PEM (Proton Exchange Membrane) electrolysis splits distilled water into hydrogen and oxygen at the natural 2:1 ratio. The membrane keeps the two streams separated so hydrogen can be delivered on its own or combined with oxygen.
Only distilled or purified water, TDS < 5 ppm. Tap or filtered mains water damages the electrolysis cell over time, and that damage isn’t covered by the warranty.
The PEM stack is rated to 10,000 hours of continuous operation — roughly 10+ years at 45 minutes a day. Backed by the 2-Year Warranty. Covers defects in materials and workmanship from the delivery date: free replacement parts with step-by-step video fitting guides; we pay the shipping in year 1, you cover it in year 2.
For delivery to the USA: free shipping, delivered duty paid with no import duties or customs fees on arrival. Up to 14 business days from order. Other destinations follow the country-specific shipping policy.
Every machine has a 2-year warranty and 90-day returns, both from delivery. Change-of-mind return shipping is paid by the buyer; we cover it if a machine arrives damaged or faulty. Support by email and WhatsApp; replacement parts shipped directly to you.
Yes. The output flow is adjustable, so you can run it at full flow or turn it down for a gentler session.
All HERO inhalation systems are built for continuous operation, but flow rate determines how many clients you can turn around. HERO Inhaler 900 and 1200 suit single-room practices, 1500 and 2000 suit busier rooms or two users on a dual cannula, and HERO Inhaler Pro 3000 is the choice where two to three concurrent users or all-day back-to-back sessions are the norm.
PEM electrolysis stacks are fed water directly. Distilled or purified water, TDS < 5 ppm, contains no dissolved minerals, so nothing is left behind on the membrane. Tap or filtered mains water deposits scale that reduces output stability, shortens stack life, and that damage isn’t covered by the warranty — which is why professional rooms keep a dedicated RO supply on site.
The 7-stage separation train removes entrained moisture and electrolyte carry-over from the gas stream after the membrane, so hydrogen leaves the machine dry. Dry gas means no liquid is drawn back through the delivery path, the internal water loop stays clean, and the membrane is not exposed to contaminants recirculating through the system during long duty cycles.
HERO Inhaler 900 and 1200 suit single-room practices, HERO Inhaler 1500 and 1800 suit busier rooms or two users on a dual cannula, and HERO Inhaler Pro 3000 is specified where two to three concurrent users or all-day back-to-back sessions are normal. Purity and PEM technology are identical across the range — flow rate is what changes.
Practitioner rooms keep a dedicated supply of distilled or purified water, TDS < 5 ppm, on site, so nothing is deposited on the PEM membrane. The HERO Purity 200-110 RO system removes the distilled-water routine, and on the gas side purity figures are manufacturer specifications unless the exact product page identifies an applicable laboratory report.
Inhalation and bath run as separate machines used in sequence, not one unit switching modes. A common professional pattern is a 20–40 minute hydrogen bath session followed by an inhalation session in the same appointment slot, so neither system becomes a bottleneck during turnaround and both draw on the same RO-pure water standard.
PEM/SPE electrolysis stacks are fed water directly, so whatever is dissolved in that water ends up at the membrane. Distilled or purified water, TDS < 5 ppm, carries no minerals to deposit, which is what keeps output stable across back-to-back client sessions. Mains or filtered tap water leaves scale on the membrane, reduces output stability, and that damage isn’t covered by the warranty.
Dissolved minerals and ions foul the catalyst-coated membrane surface, progressively blocking active area. The practical result is contamination-driven output drift: the same flow setting delivers less hydrogen over time, cell voltage rises, and the stack runs hotter. Feeding only RO-pure water avoids that mechanism entirely and is the single largest factor in system lifespan.
On the feedwater side: distilled or purified water, TDS < 5 ppm, refilled from a labelled container, with the reservoir drained before extended shutdowns. On the gas side: purity figures are manufacturer specifications unless the exact product page identifies an applicable laboratory report, with 7-stage separation delivering dry hydrogen so no moisture or electrolyte carry-over returns through the delivery path.
Purity evidence is model-specific. Report LH2025050017 covers HERO Inhaler 900, 1200, 1500, 1800 and Pro 3000. Ask before purchasing for the exact model's documentation.
Connect it to the hydrogen outlet with the supplied tubing, place it in a glass of drinking water and run the machine for a few minutes. Use it in a ventilated room, as with inhalation.
Hydrogen in the human body: what's known, and what isn't
Still have a question?
Email me before the Black Friday price ends
Black Friday price: $150 off until Nov 30. We'll email you once, a few days before it ends.
Prefer to talk first? Contact us
WhatsApp us